Eppendorf Centrifuge Model 5702
compact, quiet, high-quality low-speed centrifugation
|
|
|
|
|
We sell, supply, service and carry spare parts for these products.
All equipment servicing to manufacturer’s specs by Eppendorf factory certified technicians.
Calibration, repair, service, spare parts, Compliance Covering - IQ/OQ/PQ, calibration and validations.
On-site repairs are available for customers in Sydney, Melbourne and Brisbane.
For other areas/States, we offer a workshop service or spare parts.
| overview |
features |
technical |
accessories |
downloads |
FAQ answers |
 POCD Scientific ~ Eppendorf’s Australian distributor for Eppendorf Centrifuge Model 5702 ~ overview |
 | These are POCDS Time Critical Products - we are seriously committed to having these products in stock 24/7/365 for immediate shipping. If we are unable to immediately dispatch any of these items to you upon receiving your order we will airfreight the item from Germany at our expense to minimise the delay in getting the item to you. |
The compact Eppendorf Centrifuge Model 5702 is a quiet, high-quality centrifuge that provides exceptional value for low-speed centrifugation in the low- to mid-throughput range. It holds a remarkable amount of tubes for its size, and it quickly spins a variety of popular cell culture and blood tubes in a choice of rotors. Accommodating either fixed-angle or swing-bucket rotors, its versatility addresses your exact needs. With state-of-the-art features at an economical price, this centrifuge is sure to please you as well as your budget.
All 5702 models can be used in a range of settings, from the clinical lab to the cell culture lab. With various fixed-angle and swing-bucket rotors available, they can accommodate almost any kind of tube.
The economical centrifuge for the clinical lab. With various fixed-angle and swing-bucket rotors and an extensive range of adapters, nearly all types of tubes can be used.
Another advantage is that all rotors within the 5702 line have been designed for interchangeability.
Large-scale tasks, compact solutions The Centrifuge Model 5702, with its space-saving (12.5
x 16 in) footprint and innovative design, can accommodate a remarkable
30 x 15 ml round-bottom tubes or 20 x 15 ml conical tubes. Your choice
of fixed-angle or swing-bucket rotors provides flexibility for low-speed
centrifugation of sensitive cells and blood. The A-4-38 Swing-bucket Rotor
can spin up to four 85 ml tubes in aerosol-tight buckets at rcf up to
3,000 x g. A variety of adapters accept all common standard, conical
and blood collection tubes. For applications requiring higher tube capacity,
rectangular buckets for up to 24 x 15 ml glass tubes can be used. Two
versions of the
F-35-30-17 Fixed-angle Rotor are available for a capacity of up to 30
x 15 ml. A simple, eight-place swing-bucket rotor is also available for
15 ml conical tubes.
 POCD Scientific ~ Eppendorf’s Australian distributor for Eppendorf Centrifuge Model 5702 ~ features |
- Extremely compact
- Maintenance-free drive adjustable to speeds up to 4,400 rpm
- Swing-bucket and fixed-angle rotors accommodate a wide range of conical,
blood and standard plastic and glass tubes from 1.1 ml to 85 ml
- Automatic soft-touch locking
- Quick acceleration and deceleration
- Optimized air flow keeps samples cool
A separate short spin button makes quick spins a
snap
Convenient features for easy operation
State-of-the-art, yet simple, this centrifuge is easy to operate. The
motorized soft-touch lid makes loading and closing effortless.
The time and speed knobs allow you
to set and adjust these parameters quickly and easily: speed can be set
in rpm or rcf (g-force), eliminating the need for tedious calculations;
and settings can be changed during a run. You can also lock your settings
to protect them against unintentional adjustment.
Once the parameters are set, simply press the time knob to start your
pre-programmed run. When complete, an audible signal at the end of the
run alerts you to remove your sensitive samples; the motorized lid unlocks
automatically for easy, one-handed access.
Easy to operate
- Clear digital display and easy-to-use knobs
- Automatic soft-touch locking
- Setting in rpm or rcf
- Extremely quiet operation
- Separate short spin button
- Speed can be set from 100 rpm to 4,400 rpm in increments of 100 rpm
- Timer can be set up to 99 minutes or continuous run
 POCD Scientific ~ Eppendorf’s Australian distributor for Eppendorf Centrifuge Model 5702 ~ technical |
| Model |
5702 |
5702 R/RH |
| Dimensions, W x D x H: |
12.5 x 16 x 9.5 in
32 x 40 x 24 cm |
15 x 22.8 x 10.2 in
38 x 58 x 26 cm |
| Weight: |
44 lb
20 kg |
79 lb
36 kg |
| Max. power requirement: |
200 W |
380 W |
| Power supply: |
120 V/60 Hz
230 V/50 Hz |
120 V/60 Hz
230 V/50 Hz |
 POCD Scientific ~ Eppendorf’s Australian distributor for Eppendorf Centrifuge Model 5702 ~ accessories |
Swing-bucket and Fixed-angle Rotors for Eppendorf Centrifuge 5702 R (refrigerated)
Product features of all rotors
- Minimal heating of samples
- Quick acceleration in 25 seconds or less
- All rotors and accessories are autoclavable
(121°C, 20 min.)
A-4-38 Swing-bucket Rotor
- Choice of round buckets with optional
aerosol-tight lids or high-capacity square buckets for
round-bottom tubes
- Round buckets accommodate conical and round-bottom
tubes from 1.1 ml to 85 ml
- Square buckets accommodate round- bottom tubes
from 5 ml to 25 ml
- Optional aerosol-tight covers protect the user
from hazardous samples*
*Aerosol containment has been
tested and approved in accordance with the procedure of
Bennett et al. from the Centre for Applied Microbiology
& Research in Porton Down, CAMR, Great Britain, and
according to annex AA of the IEC 1010-2-020 safety
standard. The test procedure simulates the accidental
release of biological material (bacteria) inside the
closed rotor or closed rectangular bucket. Air and swab
samples are taken to ensure that no material is released
from the closed rectangular buckets or closed rotor
during operation.
F-35-30-17 Fixed-angle Rotor
- Available with a choice of 10 or 30 steel tube
holders
- Accommodates up to 20 x 15 ml conical tubes or 30
x 15 ml round-bottom tubes
A-8-17 Swing-bucket Rotor
- Affordable and simple rotor design
- Accommodates up to 8 x 15 ml conical or
round-bottom tubes
 |
Specifications |
|
|
| |
With round buckets |
With square buckets |
| Maximum Capacity |
4 x 85 ml |
8 x 25 ml |
| Maximum Speed |
4,400 rpm |
4,400 rpm |
| Maximum RCF |
3,000 x g |
2,750 x g |
| Maximum Radius |
137 mm |
127 mm |
| Maximum Vessel Diameter |
38 mm |
25 mm |
| Maximum Vessel Length |
121 mm |
100 mm |

Swing-bucket Rotor includes 4 x 85 ml round buckets
Type A-4-38
022639048 |

Round bucket(1) set of 4
022639081 |

Aerosol-tight cover, set of 2
022639293 |
| Tube |
(Please observe the limiting data from the tube manufacturer regarding the maximum load- bearing capacity of the tubes.) |
 |
 |
 |
 |
 |
| tube capacity (ml) |
1.1-1.4 |
2-7 |
2.6-7 |
4-10 |
9-15 |
| Max. tube length for all positions below the aerosol-tight lid (mm)* |
100 |
100 |
100 |
100 |
100 |
| Max. tube length for all positions without aerosol-tight lid (mm)* |
100 |
100 |
100 |
100 |
100 |
| Adapter |
Set of 2
|
Set of 2
|
Set of 2
|
Set of 2
|
Set of 2
|
| Catalog No. |
022639285 |
022639102 |
022639242 |
022639269 |
022639129 |
| number of tubes per adapter/per rotor |
5/20 |
5/20 |
4/16 |
4/16 |
4/16 |
| Adapter bore (dia. mm) |
8.5 |
12.5 |
13.5 |
16 |
17.5 |
| max. rcf (g-force) |
2,850 |
2,850 |
2,850 |
2,850 |
2,850 |
| Centrifugation radius (mm) |
132 |
132 |
132 |
132 |
130 |
| max. rotational speed (rpm) |
4,400 |
4,400 |
4,400 |
4,400 |
4,400 |
| Tube |
(Please observe the limiting data from the tube manufacturer regarding the maximum load- bearing capacity of the tubes.) |
 |
 |
 |
 |
 |
| Tube
capacity (ml) |
15 ml conical |
15 ml conical |
25 |
50 ml conical |
85 |
| Max. tube length for all positions below the aerosol-tight lid (mm)* |
120 |
- |
100 |
115 |
106 |
| Max. tube length for all positions without aerosol-tight lid (mm)* |
121 |
121 |
100 |
115 |
106 |
| height=65>Adapter |
Set of 2
|
Set of 2
|
Set of 2
|
Set of 2
|
Set of 2
 |
| Catalog No. |
022639188 |
022639200(2) |
022639145 |
022639226 |
022639161 |
| Number of tubes per adapter/per rotor |
1/4 |
2/8 |
1/4 |
1/4 |
1/4 |
| Adapter bore (dia. mm) |
17.2 |
17.2 |
25 |
30 |
38 |
| Max.
RCF (g-force) |
3,000 |
3,000 |
2,900 |
2,900 |
2,900 |
| Centrifugation radius (mm) |
137 |
137 |
135 |
135 |
135 |
| Max.
rotational speed (rpm) |
4,400 |
4,400 |
4,400 |
4,400 |
4,400 |
(1) Swing-bucket Rotors are supplied with
buckets of one weight class. Adapters and tubes which
together do not exceed a maximum weight of 190 g can be
put in one round bucket. The total weight of a loaded
bucket (including adapters and filled tubes) may not
exceed 375 g. The weight given on the rotor applies to
buckets including their load.
(2) Cannot be use with aerosol-tight lids.
*If maximum tube length is exceeded, the loading capacity of the adapter may be reduced. Please perform a manual swing test.
Adapter, caps and rotor are autoclavable: 121°C, 20 min.
 |
|

Swing-bucket Rotor without buckets
Type A-4-38
022639064 |

Rectangular bucket
set of 4
022639307 |
Tube |
(Please observe the limiting data from the tube
manufacturer regarding the maximum load- bearing
capacity of the tubes.) |
 |
 |
 |
 |
 |
| Tube
capacity (ml) |
5-7 |
9 |
15 |
20 |
25 |
| Max. tube length for all positions
(mm)* |
100 |
100 |
100 |
100 |
100 |
| Adapter |
Set of 2
|
Set of 2
|
Set of 2
|
Set of 2
|
Set of 2
|
| Catalog No. |
022639323 |
022639340 |
022639366 |
022639382 |
022639391 |
| Number of tubes per adapter/per rotor |
10/40 |
8/32 |
6/24 |
4/16 |
2/8 |
| Adapter bore (dia. mm) |
13 |
14.5 |
17.5 |
22 |
25 |
| Max.
RCF (g-force) |
2,750 |
2,750 |
2,750 |
2,750 |
2,750 |
| bgColor=#0e2a8a height=19>Centrifugation radius (mm) |
127 |
127 |
127 |
127 |
127 |
| Max. rotational speed (rpm) |
4,400 |
4,400 |
4,400 |
4,400 |
4,400 |
*If maximum tube length is exceeded, the
loading capacity of the adapter may be reduced. Please
perform a manual swing test.
| Tube |
(Please observe the limiting data from the tube
manufacturer regarding the maximum load- bearing
capacity of the tubes.) |
 |
 |
| Tube capacity (ml) |
15 |
15 ml conical |
| Max. tube length for all positions (mm)* |
115(3) |
inner ring: 135; outer ring: 120 |
| Catalog No. |
022639455 |
022639447 |
| Number
of tubes per rotor for versions with 30 sleeves |
30 |
20 |
| Sleeves (dia. mm) |
18 |
18 |
| Max. RCF (g-force) |
2,750 |
2,700 |
| Centrifugation radius (mm) |
127 |
125 |
| Max. rotational speed (rpm) |
4,400 |
4,400 |
(3) 105 with a load of conical tubes and round-bottom tubes.
24-place microcentrifuge Rotor F-45-24-11
 |
- Max. rcf: 1,700 x g
- Low-noise centrifugation without rotor lid
- Autoclavable (121°C, 20 min)l Centrifugation
of 1.5 ml and 2 ml Eppendorf Tubes®
- Adapter for:
- 0.2 ml PCR tubes
- 0.4
ml centrifuge tubes
- 0.5 ml micro test tubes
and 0.6 ml Microtainer® tubes
|
18-place Screw-cap/cryovial Rotor F-45-18-17-Cryo
 |
- Max. rcf: 1,840 x g
- Low-noise centrifugation without rotor lid
- Rotor and adapter autoclavable (121°C, 20
min)
- Centrifugation of 1 ml-2 ml Cryotubes® (max. 13 mm, can be used
with adapter) and
screw-cap centrifugation
tubes (max. 17 mm, can be used directly)
|
 |

Swing-bucket Rotor,
8 x 15 ml
Type A-8-17
022639501 |
| Tube |
(Please observe the limiting data from the tube
manufacturer regarding the maximum load- bearing capacity of the tubes.) |
 |
 |
| Tube capacity (ml) |
15 |
15 ml conical |
| Max. tube length for all positions (mm)* |
120 |
120 |
| Catalog No. for adapters |
022639510 |
022639528 |
| Number of tubes per rotor |
8 |
8 |
| Sleeves (dia. mm) |
18 |
18 |
| Max. RCF (g-force) |
2,750 |
2,700 |
| Centrifugation radius (mm) |
128 |
128 |
| Max. rotational speed (rpm) |
4,400 |
4,400 |
*If maximum tube length is exceeded, the loading capacity of the adapter may be reduced.
 POCD Scientific ~ Eppendorf’s Australian distributor for Eppendorf Centrifuge Model 5702 ~ downloads |
| Document |
Size |
download |
| 5702/5702R/5702RH manual |
1200 KB |
 |
| One...Two...Three - the 5702 family |
2.6 MB |
 |
| Aerosol-tight 85ml Round Bucket - instructions |
87 KB |
 |
| Instructions for using Rotors |
56 KB |
 |
These are PDF files, to obtain a free Adobe PDF reader:  |
 POCD Scientific ~ Eppendorf’s Australian distributor for Eppendorf Centrifuge Model 5702 ~ FAQs |
| Is it possible to operate the Centrifuge 5702 in the cooling room? |
 |
Yes, the Centrifuge 5702 may be operated in the cooling room. When moving the centrifuge from the cooling room to a normal lab room, the centrifuge must either run warm for half an hour in the cooling room or warm up for at least 3 hours in the lab room without being connected to the power supply. This is to avoid damage caused by condensation.
| Is it possible that the time is counted down only after reaching the selected speed? |
 |
Yes, this is possible. Pressing the START/STOP key for longer than 2 s with the centrifuge lid open initiates the switch to the "at set rpm" mode, as symbolized by a pictogram.
To exit the "at set rpm" mode again, press the START/STOP key again for longer than 2 s with the centrifuge lid open, until the pictogram appears.
| Is it possible to change the acceleration and braking ramps for specific applications? |
 |
Yes, when working with Ficoll density gradients or other sensitive applications (e.g. certain blood and urea centrifugations), slower acceleration and braking ramps can be set for the Centrifuge 5702 / 5702 R / 5702 RH. This allows the centrifuge to accelerate and decelerate smoothly and ensures optimum centrifugation results. Press the SHORT key for more than 5 s while the centrifuge lid is open. The writing on the display changes from "br on" (brake on) to "br OF" (brake off), or "soft" is displayed (5702 R, 5702 RH). The slower acceleration and braking ramps are now activated. If the SHORT key is pressed for less than 5 s while the centrifuge lid is open, the current state is displayed.
| Is aerosol-tight centrifugation possible in the Centrifuge 5702 / 5702 R / 5702 RH? |
 |
Yes, there are aerosol-tight caps available for the round buckets of the rotor A-4-38. These caps are certified according to Porton Down. All round bucket adapters, except for the adapter 5702 723.002, can be used for aerosol-tight centrifugation. Instead of the adapter 5702 723.002 for two 15 ml Falcon tubes each, the adapter 5702 732.001 for one 15 ml Falcon tube is available for aerosol-tight centrifugation.
| Is it possible to switch off the signal tone? |
 |
Yes. If the OPEN key is pressed for longer than 2 s while the centrifuge lid is open, either "b on" (signal tone on) or "b of" (signal tone off) will appear.
With the Centrifuges 5702 R / 5702 RH, a pictogram on the display indicates that the signal tone is switched on.
| Is it also possible to adjust the parameters during centrifugation? |
 |
Adjustments to the time, rotational speed and temperature (5702 R / 5702 RH only) can be made while the centrifuge is running. To do this, press the SHORT key until the display begins to flash. You can now set the new centrifugation parameters using the TIME and SPEED dials and the TEMP keys. The new centrifugation parameters are taken over after 5 s.
| Can the values set for routine applications be secured against unintentional adjustment? |
 |
Yes, with the Centrifuges 5702 / 5702 R / 5702 RH it is possible to fix the desired settings. To do this, press the SHORT and the OPEN keys simultaneously for at least 5 s while the centrifuge lid is open. In this way, the dial adjustment is deactivated and "lo on" will appear on the display of the Centrifuge 5702. On the display of the Centrifuges 5702 R / 5702 RH, the fixed setting of the centrifugation parameters will be indicated by an additional pictogram. The set values can now no longer be adjusted, irrespective of whether the centrifuge is running or not. In order to reactivate the dial adjustment, press the SHORT and OPEN keys again for 5 s. "lo of" will appear on the display of the Centrifuge 5702, and the pictogram on the display of the Centrifuges 5702 R / 5702 RH will change. The parameters can now be adjusted again.
| Are the rotors and adapters autoclavable? |
 |
All rotors, buckets, adapters, sleeves and caps are autoclavable for 20 min. at 121°C. The rotors A-4-38 and F-35-30-17 as well as the affiliated buckets and sleeves can even be autoclaved for 2 hrs. at 140°C and 3 bar.
| How can the centrifuge be opened in the case of power failure? |
 |
First, pull the plug and wait until the rotor comes to a standstill (can take up to 5 minutes!). The emergency lid release is located on the bottom of the device: a small, white plastic button is located in the base plate in front of the front right device foot. Remove this and pull the cord vertically downwards. The lid will open.
Please ensure that the cord retracts completely into the housing when you later close the lid. Press the plastic button back into the base plate.
| How can the rotors and adapters be cleaned? |
 |
Rotors, buckets, sleeves and adapters should be cleaned on a monthly basis with a neutral detergent (i.e. Extran neutral, RBS neutral, Teepol 610S or 70 % alcohol, Meliseptol, Sterilium) in order to prevent material changes due to residues of the material being centrifuged. Please do not use sodium hypochlorite or oxidizing disinfectants or detergents that contain chlorine under any circumstances. Disinfection with glutaraldehyde solution is possible. We recommend Cidex r activated glutaraldehyde solution (r : Johnson & Johnson). Plastic adapters and rubber inlays are dishwasher safe.
| How can the relative centrifugal force (rcf) for the various adapters be exactly determined? |
 |
The rcf (g-force) shown on the display is standardized for 15 ml Falcon tubes (rotor: A-4-38). The rcf to be attained at maximum speed for the various adapters are listed in the operating manual. In order to determine a specific rcf for a specific adapter, use the following formula according to DIN 58970:
rcf = 1.118 · 10-5 · n2 · rmax n: rotational speed in rpm
rmax: max. centrifugation radius in cm
| Which material is the rotor chamber made of? |
 |
The rotor chamber is made of high-quality steel and is therefore extremely resistant.
| What is the minimum selectable speed and in which increments can it be increased? |
 |
The minimum selectable speed is 100 rpm. It can be increased in increments of 100. The g-forces displayed are only approximations. The exact values can be calculated for the different adapters. Please bear in mind that a setting of 100 rpm equals a relative centrifugal force of 1.5 x g. The 100 x g displayed is only reached at a rotational speed of 800 rpm.
| How can the set parameters be saved using the program keys? |
 |
This is only possible when the centrifuge is not running. First, set the desired program parameters using the TIME and SPEED dials and the TEMP arrow keys. The "at set rpm" function and the slower acceleration and braking ramps can also be saved in the fixed programs, if required. Keep the PROG 1 or PROG 2 key pressed for 2 s until the program key stops flashing and glows continuously. A short signal tone will sound. The program has been saved.
| Can the ShortSpin key be programmed? |
 |
No, the ShortSpin key cannot be programmed.
| What are the maximum values for the acceleration and deceleration times? |
 |
The acceleration time to the maximum rotational speed is less than 25 s, the deceleration time from the maximum rotational speed is approx. 25 s.
| Are any rotors for 1.5/2.0 ml micro test tubes or microplates available for Centrifuge 5702 / 5702 R / 5702 RH? |
 |
The centrifuge has a fixed-angle rotor for 1.5/2.0 ml micro test tubes. With the help of adapters, tubes with a volume of 0.2 - 0.6 ml can also be used. A rotor for microplates, however, is not available.
| What is the maximum number of 15 ml Falcon tubes that can be centrifuged in the fixed-angle rotor F-35-30-17 or in the swing-bucket rotor A-4-38? |
 |
A maximum of 20 x 15 ml Falcon tubes can be centrifuged in the fixed-angle rotor F-35-30-17. The maximum capacity of the swing-bucket rotor A-4-38 is 8 x 15 ml Falcon tubes. Aerosol-tight centrifugation is only possible with 4 x 15 ml Falcon tubes in the swing-bucket rotor.
|